Prevena Plus 125 Therapy Unit⁚ A Comprehensive Guide

This guide provides a comprehensive overview of the Prevena Plus 125 Therapy Unit‚ a single-use‚ disposable device designed for managing the environment of closed surgical incisions․ The unit delivers continuous negative pressure at 125 mmHg‚ aiding in the reduction of seroma and surgical site infections․ This guide covers the purpose‚ benefits‚ intended use‚ features‚ components‚ and how the system works․ It also includes safety information‚ application instructions‚ troubleshooting tips‚ home care recommendations‚ and frequently asked questions․

Introduction

The Prevena Plus 125 Therapy Unit is a single-use‚ disposable device designed for managing the environment of closed surgical incisions; This innovative system utilizes continuous negative pressure at 125 mmHg to aid in the reduction of seroma formation and‚ in patients at high risk for post-operative infections‚ aid in reducing the incidence of superficial surgical site infection․ The Prevena Plus 125 Therapy Unit is a crucial tool for postoperative recovery‚ and understanding its functionality and proper use is essential for optimizing patient outcomes․

What is the Prevena Plus 125 Therapy Unit?

The Prevena Plus 125 Therapy Unit is a single-use‚ disposable device designed for managing the environment of closed surgical incisions․ This innovative system utilizes continuous negative pressure at 125 mmHg to aid in the reduction of seroma formation and‚ in patients at high risk for post-operative infections‚ aid in reducing the incidence of superficial surgical site infection․ The unit consists of a therapy unit‚ an incision dressing‚ and a canister․ The therapy unit provides the negative pressure‚ while the incision dressing creates a sealed environment around the surgical incision․ The canister collects drainage from the incision․

Purpose and Benefits

The Prevena Plus 125 Therapy Unit is designed to manage the environment of closed surgical incisions and remove fluid away from the surgical incision via the application of -125mmHg continuous negative pressure․ This continuous negative pressure helps to reduce the risk of complications such as seroma formation‚ a fluid buildup under the skin‚ and surgical site infections․ The unit’s benefits include promoting wound healing‚ reducing pain and discomfort‚ and minimizing the need for additional surgical interventions․

Intended Use

The Prevena Plus 125 Therapy Unit is specifically intended for use in managing the environment of clean‚ closed surgical incisions that continue to drain following sutured or stapled closure․ It is designed to be used in a variety of surgical specialties‚ including orthopedic‚ plastic reconstructive‚ vascular‚ and general surgery; The unit can be applied to various surgical wounds‚ such as incisions from total knee replacements‚ breast augmentations‚ abdominal surgeries‚ and more․ The Prevena Plus 125 Therapy Unit aims to facilitate optimal wound healing and minimize complications associated with post-operative fluid accumulation and infection․

Features and Functionality

The Prevena Plus 125 Therapy Unit boasts several features designed for efficient and safe wound management․ It utilizes 3M’s SensaT․R․A․C; Technology‚ which provides controlled negative pressure to the wound site․ This technology allows for continuous suction‚ effectively removing fluid from the incision and promoting healing․ The unit also incorporates the Visicheck Feature‚ a visual indicator that helps assess the integrity of the dressing and detect potential leaks․ This feature utilizes a series of lights to indicate the suction strength and alerts users if the dressing needs attention․ The unit also features an alert mute button‚ allowing users to temporarily silence the audible alert for two minutes․ The Prevena Plus 125 Therapy Unit is equipped with a rechargeable battery‚ providing a convenient and long-lasting power source for continuous therapy․

How it Works

The Prevena Plus 125 Therapy Unit operates by applying continuous negative pressure to the surgical incision‚ creating a closed environment that promotes healing and reduces complications․ The unit’s suction mechanism draws fluid away from the wound site‚ reducing the risk of seroma formation and infection․ The negative pressure is generated by a small pump within the unit‚ which draws air out of the canister connected to the dressing․ This creates a vacuum effect that pulls fluid from the wound into the canister․ The unit’s battery provides continuous power for the suction mechanism‚ ensuring uninterrupted therapy․ The Prevena Plus 125 Therapy Unit also includes a visual indicator‚ known as the Visicheck Feature‚ which helps monitor the effectiveness of the suction and alerts users to potential issues such as leaks or blockages․

Negative Pressure Application

The Prevena Plus 125 Therapy Unit employs a unique method of applying continuous negative pressure to the surgical incision․ This pressure‚ maintained at a constant -125mmHg‚ plays a crucial role in managing the wound environment․ The negative pressure works by creating a vacuum effect‚ drawing fluid away from the incision site and promoting healing․ The unit’s internal pump generates this suction‚ effectively removing excess fluid and reducing the risk of complications like seroma formation and infection․ This consistent suction helps maintain a closed wound environment‚ minimizing exposure to external contaminants and promoting optimal healing conditions․

Drainage Collection

The Prevena Plus 125 Therapy Unit incorporates a specialized canister for collecting drainage fluid from the surgical incision․ This canister is securely attached to the therapy unit and plays a vital role in maintaining the negative pressure system․ As the unit draws fluid away from the incision‚ it is collected within the canister‚ effectively removing it from the wound environment․ The canister’s capacity allows for efficient fluid removal‚ minimizing the risk of accumulation and promoting healing․ Regular monitoring of the drainage volume is essential to ensure proper system function and identify any potential issues․

Battery Life and Charging

The Prevena Plus 125 Therapy Unit is powered by a rechargeable battery‚ providing continuous negative pressure for extended periods․ Upon receipt of the therapy unit‚ the battery may not be fully charged․ It is crucial to ensure that the battery is adequately charged before applying the dressing to maintain optimal system performance․ The unit’s battery life varies depending on factors such as usage duration and environmental conditions․ Regular monitoring of the battery level is recommended‚ and recharging should be initiated as needed to prevent interruption of therapy․ The manufacturer provides specific instructions for charging the battery‚ which should be strictly followed to ensure safe and effective operation․

Components of the System

The Prevena Plus 125 Therapy System comprises several key components‚ each playing a crucial role in delivering effective wound management․ These components work in synergy to maintain a controlled environment around the surgical incision‚ promoting healing and minimizing complications․ The system includes the Therapy Unit‚ the Incision Dressing‚ and the Canister․ The Therapy Unit is the central component‚ providing the power source and negative pressure to the system․ The Incision Dressing‚ a sterile‚ adhesive dressing‚ directly covers the surgical wound‚ creating a sealed environment․ The Canister‚ a disposable container‚ collects drainage fluid from the wound․ Each component is meticulously designed to ensure optimal performance and patient safety․

Therapy Unit

The Prevena Plus 125 Therapy Unit is the heart of the system‚ responsible for generating and maintaining the continuous negative pressure․ This compact‚ battery-powered unit is designed for portability and ease of use․ The Therapy Unit features a user-friendly interface with clear indicators and alerts‚ providing real-time feedback on system performance․ It also incorporates Sensat․R․A․C․ Technology‚ which enables the unit to monitor and adjust the pressure based on the wound environment․ The unit is equipped with a battery that provides up to 14 days of continuous operation‚ minimizing the need for frequent recharging․

Incision Dressing

The Prevena Plus 125 Incision Dressing is a key component of the system‚ designed to create a closed environment around the surgical incision․ It is a sterile‚ single-use dressing that consists of a transparent film layer‚ a foam layer‚ and a drain tube․ The transparent film layer provides a barrier against external contamination‚ while the foam layer absorbs excess fluid and helps maintain negative pressure․ The drain tube connects to the Therapy Unit‚ allowing for fluid removal from the wound site․ The dressing is designed to be comfortable and flexible‚ allowing for patient mobility․

Canister

The Canister is an integral part of the Prevena Plus 125 Therapy Unit‚ serving as a collection vessel for drainage fluid removed from the surgical incision․ It is a disposable‚ sterile container that attaches securely to the Therapy Unit․ The Canister is designed to hold a specific volume of drainage‚ and it features a clear window that allows for easy visual monitoring of the fluid level․ When the Canister is full‚ it needs to be replaced with a new one to maintain the effectiveness of the negative pressure therapy; The Canister plays a vital role in ensuring efficient drainage and maintaining the integrity of the closed wound environment․

Prevena Plus 125⁚ Indications and Contraindications

The Prevena Plus 125 Therapy Unit is indicated for use in managing the environment of clean closed surgical incisions that continue to drain following sutured or stapled closure․ It is intended to aid in reducing the incidence of seroma and‚ in patients at high risk for post-operative infections‚ aid in reducing the incidence of superficial surgical site infection․ The unit is designed for use in various surgical specialties‚ including orthopedic‚ plastic reconstructive‚ vascular‚ and general surgery․ However‚ there are specific contraindications that need to be considered before using the Prevena Plus 125 Therapy Unit․ These contraindications include‚ but are not limited to‚ active infections‚ open wounds‚ wounds with exposed organs or blood vessels‚ and wounds with compromised tissue integrity․

Indications

The Prevena Plus 125 Therapy Unit is indicated for use in managing the environment of clean closed surgical incisions that continue to drain following sutured or stapled closure․ It is intended to aid in reducing the incidence of seroma and‚ in patients at high risk for post-operative infections‚ aid in reducing the incidence of superficial surgical site infection․ The unit is designed for use in various surgical specialties‚ including orthopedic‚ plastic reconstructive‚ vascular‚ and general surgery․ Specifically‚ the Prevena Plus 125 Therapy Unit is indicated for use in patients who have undergone procedures such as knee arthroplasty‚ total hip arthroplasty‚ breast reconstruction‚ abdominal surgery‚ and other procedures where drainage is anticipated․

Contraindications

The Prevena Plus 125 Therapy Unit is contraindicated in certain situations․ It should not be used on patients with open wounds‚ wounds with suspected infection‚ or wounds with exposed bone‚ tendon‚ or other vital structures․ Additionally‚ the unit should not be used on patients with active bleeding‚ known allergies to any component of the system‚ or on wounds that are not adequately closed․ It is essential to consult with a healthcare professional to determine if the Prevena Plus 125 Therapy Unit is appropriate for your specific situation․ The device should not be used in areas of the body where it could interfere with vital functions‚ such as the neck‚ chest‚ or face․ It is important to follow the instructions provided by your healthcare provider and to consult with them if you have any concerns or questions about the use of the Prevena Plus 125 Therapy Unit․

Prevena Plus 125⁚ Safety Information and Precautions

The Prevena Plus 125 Therapy Unit is a safe and effective device when used as directed‚ but it is essential to follow all safety guidelines and precautions․ The unit should only be used by qualified healthcare professionals or under their supervision․ The dressing should be applied and maintained according to the instructions provided․ It is crucial to monitor the system closely for any signs of complications‚ such as infection‚ bleeding‚ or excessive drainage․ The unit should not be used on patients with known allergies to any component of the system․ It is important to avoid contact with the unit’s electrical components and to keep the unit dry․ The system should be stored in a cool‚ dry place․ If you have any questions or concerns about the safety of the Prevena Plus 125 Therapy Unit‚ please contact your healthcare provider․

Warnings

The Prevena Plus 125 Therapy Unit is not intended for use in patients with open wounds or wounds that are actively bleeding․ It is crucial to ensure that the incision is closed and free of any debris or foreign objects before applying the dressing․ The dressing should not be applied over areas of skin that are inflamed‚ infected‚ or compromised․ The unit should not be used in patients who are pregnant or breastfeeding․ The unit should not be used in patients with a history of deep vein thrombosis or pulmonary embolism․ The unit should not be used in patients with a history of allergies to silver or other components of the dressing․ The unit should not be used in patients with a pacemaker or other implanted electronic devices․ The unit should not be used in patients who are receiving radiation therapy․

Precautions

The Prevena Plus 125 Therapy Unit should be used only as directed by a healthcare professional․ It is important to follow all instructions for use and safety information provided in the package insert and clinician guide․ The unit should not be used on any other wounds or incisions other than those for which it is intended․ Do not modify or alter the unit in any way․ If the unit malfunctions or experiences any problems‚ discontinue use and contact your healthcare provider․ Store the unit in a cool‚ dry place away from direct sunlight and heat․ Keep the unit out of reach of children and pets․ Do not use the unit if the packaging is damaged or tampered with․ Dispose of the unit properly according to local regulations․ The unit should not be used in patients with a history of allergies to silver or other components of the dressing․ The unit should not be used in patients with a pacemaker or other implanted electronic devices․ The unit should not be used in patients who are receiving radiation therapy․

Prevena Plus 125⁚ Application and Use

The Prevena Plus 125 Therapy Unit is designed for ease of use‚ but it is crucial to follow the correct application and use procedures for optimal results․ The application process involves preparing the surgical site‚ applying the dressing‚ securing the unit‚ and monitoring the system regularly․ Prior to application‚ ensure the surgical site is clean and dry․ The dressing should be applied to the incision site‚ ensuring it adheres securely to the surrounding skin․ The therapy unit should be firmly attached to the dressing‚ ensuring a secure connection․ Regularly monitor the system for any leaks‚ drainage volume‚ and alerts from the unit․ The unit includes a Visicheck feature that indicates the leak rate‚ allowing for timely adjustments to ensure proper suction and drainage․ Refer to the user manual for detailed instructions on applying and using the Prevena Plus 125 Therapy Unit․

Preparing for Application

Before applying the Prevena Plus 125 Therapy Unit‚ it is essential to prepare the surgical site and ensure a clean and dry environment․ Begin by thoroughly cleansing the incision and surrounding skin with a mild antiseptic solution․ Allow the area to air dry completely before proceeding with the dressing application․ If the incision is located near the umbilicus‚ ensure the umbilicus is fully filled with antimicrobial petroleum gauze prior to applying the dressing․ This step is crucial for preventing potential complications related to the umbilicus․ Furthermore‚ ensure the patient is comfortable and positioned appropriately before initiating the dressing application process․

Applying the Dressing

Carefully remove the Prevena Plus 125 Incision Dressing from its packaging‚ ensuring sterility is maintained․ Position the dressing over the surgical incision‚ aligning the center of the dressing with the incision․ Gently smooth out any air bubbles or wrinkles to ensure a secure seal․ Using the provided patch strips‚ carefully seal the edges of the dressing to the skin․ Make sure the patch strips are applied firmly and evenly‚ creating a watertight barrier․ After securing the dressing‚ inspect the Visicheck feature on the therapy unit․ This feature helps assess the seal integrity by indicating the leak rate․ If a marginal leak rate is detected‚ ensure the canister is locked into the unit‚ and follow the manufacturer’s instructions for addressing the leak․

Securing the Unit

Once the dressing is securely applied‚ connect the therapy unit to the dressing․ Align the connector on the unit with the port on the dressing and press firmly until you hear a click‚ ensuring a secure connection․ Next‚ attach the canister to the unit․ Align the canister with the unit’s receptacle and press firmly until it locks into place․ The canister should be securely attached to the unit and not easily dislodged․ After connecting the canister‚ visually check for any leaks around the connections between the unit‚ canister‚ and dressing․ If any leaks are observed‚ carefully re-secure the connections and re-check for leaks․ Once the unit is securely attached and no leaks are present‚ the Prevena Plus 125 system is ready for use․

Monitoring the System

Regularly monitor the Prevena Plus 125 Therapy Unit for proper functioning and any potential issues․ The unit has built-in indicators and alerts to help you identify and address problems․ Pay attention to the unit’s display and any audible alerts․ The unit’s display will indicate the battery life‚ therapy status‚ and any alerts․ The unit will also emit audible alerts for low battery‚ canister full‚ or leaks․ If you notice any alerts or unusual behavior‚ refer to the troubleshooting guide in the instruction manual․ Check the dressing for any signs of leaks‚ loosening‚ or damage․ If you observe any issues‚ address them promptly to ensure the system continues to function effectively and maintain the intended negative pressure․

Prevena Plus 125⁚ Troubleshooting and Alerts

The Prevena Plus 125 Therapy Unit has built-in indicators and alerts to assist in identifying and resolving any potential issues․ The unit’s display will show the battery life‚ therapy status‚ and any alerts․ The unit also emits audible alerts for low battery‚ canister full‚ or leaks․ The Visicheck feature provides a visual indication of the dressing’s seal․ If the Visicheck feature indicates a Marginal leak rate condition‚ ensure the canister is locked into the unit․ The unit may also display alert codes for specific issues․ Refer to the troubleshooting guide in the instruction manual for detailed information on each alert code and recommended actions․ If the problem persists‚ contact your healthcare provider for assistance․

Indicators and Alerts

The Prevena Plus 125 Therapy Unit features a user-friendly interface that provides visual and audible indicators to alert you of the system’s status․ The display screen shows the battery life‚ therapy status‚ and any alerts․ The unit also emits audible alerts for low battery‚ canister full‚ or leaks․ The Visicheck feature provides a visual indication of the dressing’s seal․ The Visicheck feature has three different light indicators to show the seal status⁚ one light (best)‚ two lights (good)‚ and three lights (marginal); If the Visicheck feature indicates a Marginal leak rate condition‚ ensure the canister is locked into the unit․ The unit may also display alert codes for specific issues․ Refer to the troubleshooting guide in the instruction manual for detailed information on each alert code and recommended actions․ If the problem persists‚ contact your healthcare provider for assistance․

Troubleshooting Common Issues

While the Prevena Plus 125 Therapy Unit is designed for reliable operation‚ you may encounter some common issues․ If the unit displays an alert or malfunctions‚ refer to the troubleshooting guide in the instruction manual for detailed instructions․ Some common issues include low battery‚ canister full‚ leaks‚ and dressing detachment․ To address low battery‚ ensure the unit is connected to a power source and allow it to charge completely․ For a full canister‚ replace the canister with a new one․ Leaks can be addressed by checking the dressing for any tears or loose connections․ Ensure the dressing is securely attached to the skin and apply additional dressing patch strips if needed․ If the dressing detaches‚ consult your healthcare provider for assistance in reapplying the dressing․

Prevena Plus 125⁚ Home Care and Maintenance

Once you’ve been discharged from the hospital‚ you’ll need to continue using the Prevena Plus 125 Therapy Unit at home to ensure optimal wound healing․ Proper home care and maintenance are essential for the unit’s functionality and to prevent any complications․ The unit should be kept in a clean and dry environment‚ away from direct sunlight and extreme temperatures․ Regularly inspect the dressing for any signs of damage or leaks․ If you notice any issues‚ contact your healthcare provider immediately․ The battery should be charged regularly to ensure continuous operation․ Follow the battery maintenance instructions provided in the manual․ Keep the unit’s canister clean and empty it when needed․ By following these guidelines‚ you can ensure proper home care and maintain the effectiveness of the Prevena Plus 125 Therapy Unit․

Home Therapy Unit

The Prevena Plus 125 Therapy Unit is designed for both hospital and home use․ When transitioning from hospital care to home care‚ the unit needs to be replaced with a dedicated home therapy unit‚ such as the Prevena Plus 125 or ACTIV․A․C․ Therapy Unit; The home therapy unit is specifically designed for use in a domestic setting and is equipped with features that make it easier to manage at home․ The unit should be kept in a clean and dry environment‚ away from direct sunlight and extreme temperatures․ Regularly inspect the dressing for any signs of damage or leaks․ If you notice any issues‚ contact your healthcare provider immediately․ The battery should be charged regularly to ensure continuous operation․ Follow the battery maintenance instructions provided in the manual․ Keep the unit’s canister clean and empty it when needed․ By following these guidelines‚ you can ensure proper home care and maintain the effectiveness of the Prevena Plus 125 Therapy Unit․

Battery Maintenance

The Prevena Plus 125 Therapy Unit is powered by a rechargeable battery‚ providing continuous negative pressure for extended periods․ Upon initial receipt of the unit‚ the battery may not be fully charged․ It is crucial to charge the battery completely before using the unit for the first time․ Regularly charge the battery to ensure uninterrupted operation․ The unit’s display indicates the battery level‚ providing a visual cue for when charging is necessary․ Always use the provided charger and follow the charging instructions carefully․ Avoid overcharging the battery‚ as this can shorten its lifespan․ Store the unit in a cool and dry place when not in use․ Proper battery maintenance helps ensure optimal performance and extends the unit’s operational life․ If you experience any issues with the battery‚ consult the manual or contact your healthcare provider for assistance․